fluke 8846a read issue
Hi all, I have a fluke 8846 multimeter that im using to measure temperature , i need to log the data with labview , for this i donwloaded the ni drivers for my fluke 8846 , but whe i run the examples...
View ArticleBasic questions about agilent34420a and drivers
Hi everybody! I have a few questions.1) Сan anybody help me and tell where can find driver for Agilent34420A on RS232. On support CD which was together with the device i find only Agilent IO 15 and...
View ArticleBK Precision device works in VISA test panel but fails when using driver
I am trying to control a BK Precision XLN power supply. I have set it up as a TCPIP VISA instrument using sockets (port 5025). It validates fine in NI MAX, and when using the VISA test panels I can...
View ArticleRemote laboratory for Microcontroller
1....I amworking on project Remote laboratory for Microcontroller ..I want to load HEX file into microcontroller remotly..Is it possible ?How? Detail-Atmega8 controller ,want to load...
View ArticleINFUSION PUMP
Hi, I'm trying to drive an 'PILOT C syringe pump made by Fresenious, using Labview.using RS232 protocol and I was wondering if I could use the NI-VISA driver software to drive these pumps?Can you...
View ArticleEnet 1000 with Enet 100 driver?
Dear all,I want to upgrade an analytical system with the Enet 1000 und Win 7. The same setup is working with a Enet under XP.Is it possible to use the Enet 1000 with an Enet 100 driver? I can`t get the...
View ArticleDevice not showing up in VISA interactive control
Hello, I am trying to access a NI USB-6251 device through VISA (pyvisa). However, the device does not show up in the VISA interactive control panel. In MAX it shows up properly and the test panel works...
View ArticleAgilent E4980A lcr meter reading high D at high frequency
Hi I have a quick question on my agilent E4980A. At high frequencies ( i.e. 100MHZ using the agilent E1645 test lead) I get high Df readings. What could be causing this?. Thank you
View ArticleMax unable to detect my HP 33120a function generator
Hi I am working on a system which setup by someone else who is no more acessible. It worked pretty well until some day, it gave me some "time out" error message. I spent a lot of time trouble shooting,...
View ArticleASRL Number in MAX differ from COM Number in
Hello, I have install the external "PCI 8S Serial card RS-232" (Model EX-41098-2 from EXSYS). In Windows Device Manager ports for this card named from COM1 to COM8 (see screenshot). In NI MAX all ports...
View ArticleUSBTMC: host continuously sending bulk OUT packets
Hi,We are developing firmware for a new TMC device. Device is successfully enumerated as IVI class [Refer: 1_WinDeviceMgr.png]The firmware is at a very basic level at this stage with Control EP...
View ArticleCan#T Evaluate LabView, get only errors
Hi,just want to evaluate LabView, but get only errors. Do installation, works, searched & installed drivers, Agilent 34401 or Agilent 33120A, the classics I think, abd open an example ==> error....
View ArticleCan't Load Tulip
I've been trying for the last week or so to get Labview (7.1) to work with an HP-Agilent-Keysite 82350A GPIB under Windows XP. I've read through a lot of the Forum posts and gleaned some valuable...
View ArticleDeploy a .NET app with NI dlls?
Hello all, I hope I have the right place here. I have a .NET utility I wrote in C# in Visual Studio 13 which I'd like to make freely available. It uses the NationalInstruments.Common and...
View ArticleAGILENT HANDHELD U1732B LCR METER
Would like to be able to log the data from my handheld Agilent U1732B LCR meter but cannot find any drivers on the forum or NI drivers page. Using the Agilent data logging program for the meter...
View Article"ENOL : No Listener (2)"
I am programing for control the oscilloscope(Tektronix DPO70604C) with GPIB-USB-HS.My development environment is Visual Studio 2012 C# and use "NI-488.2 Language Interface(LangInt.dll)" for control...
View ArticleVISA and Enet/100/1000 hangs
I am running 50 Enet/1000 /100 controllers from one PC windows7 server. Each controller ruins 4 instruments configured the same way. It is essential that all measurements starts at the same time so my...
View ArticleNI USB-8473 Driver Corrupt
Good Afternoon, I have successfully downloaded, installed, and used the NI-CAN 14.0 driver onto my laptop.However the unzip+install process fails when I try to copy the same installer onto a new PC...
View ArticleVI_NULL constant expression required
The VBA program with NI-VISA 4.6.2 can run ok , but will get the error(NI_NULL display constant expression required) when run in another computer with verion NI-VISA 5.2 .The VBA program have loaded...
View Article