RS232C--VEE program--(LCR-106X)
When I use an RS232C device connected to my computer via the Keysight VEE program (or via another software), an error appears: "Bus error occurred?”. Via IO libraries, an error appears when I try to...
View ArticleRigol 1054 via LAN
Hello All, I am trying to connect rigol 1054z oscilloscope with labview via LAN.I downloaded rigol driver and example.When DC voltage is measured, there is inverted value on labview.Please check...
View ArticleSystem.Reflection.TargetInvocationException in communication via GPIB-USB-HS
Hi there. I am trying write code in VB.net language and communicate with Keithley electrometer via GPIB-USB-HS with NI-VISA language.While debugging my vbproj codes, I encounterer the following...
View ArticleProcessor Compatibility for PCIe GPIB card
Does PCIe-GPIB card (Part Number: 778930-01) require an enterprise Intel Xeon processor or AMD Threadripper to run or any standard consumer range such as Intel Core i-Series & AMD Ryzen is...
View ArticleConnecting Agilent 8164b over rs232
Hello everyone,I am trying to connect a agilent 8164b over Serial. If i try *idn? over NI MAX i get a timeout error.I matched settings and baudrate of the computer and the device and I am using a null...
View ArticleLabView Cannot find units problem with Hardvard 11 Pico Plus Elite pump
Hello, I am having a difficulty to use LabView driver to control Hardvard 11 Pico Plus Elite pump. When I used the driver to run the pump, the LED of the pump was only flashing and the pump didn't...
View ArticleTwo instances of power supply showing up in MAX
Hello, I have two power supply mainframes connected to my PC via ethernet (Keysight N6700C and N6701C). I have set the IP addresses of these devices via telnet to a static IP address. MAX keeps showing...
View Articlevisa works with highlight execution
I'm trying to modify the example provided by Omega to read from a PX409 pressure transducer. The code used to verify that the sensor is present only works when I run the vi in highlight execution mode...
View ArticleJust installed DAQmx on Windows 10 and it not recognizing my NI 9211 in my NI...
Windows 10 is not recognizing my NI 9211 in my NI USB-9162 carrier. I am just getting back into this stuff, I have been away from this for the last decade or so I am on a relearning curve, so please...
View ArticleUSB-GPIB-A
Hi! Friends, tell me if anyone has a driver for USB-GPIB-a V. 2. 2? I found an old device, and the modern one no longer supports such an old one.
View Article求助:支持Agilent E4403B的GPIB-USB-HS驱动
环境:Windows 10现有一个NI4882_312版本的驱动,可以正常用GPIB-USB-HS连接Agilent E4438C仪器,且正常控制。但是在NI-MAX中无法识别到Agilent E4403B仪器。求助:支持Agilent E4403B的GPIB-USB-HS驱动。
View ArticleNI PCIe-8430/8 fails self test
I bought the NI PCIe-8430/8 and installed the drivers that came with the cd. The device and the COM ports show up correctly in device manager and NI Max but the NI-Serial Troubleshooter fails when it...
View ArticleBarcoder reader interface with labview
i have Honeywell Barcode Reader Model No:-1450 with usb interface.How i can proceed with labview to program it.
View ArticleSet amplitude in Agilent N5181A
Hi. I want to set amplitude value in Agilent N5181A. Vaule - flaot type, unit is DBM, DBUV, DBUVEMF, V, VEMF,DB.When i try set frequency it's work, but i can't undertstand. Why i can't set amplitude ?...
View Articletimeout error on ibclr
I am using an old version of the ni 488 driver on a red hat 4 Linux machine. We have a 5 GPIB instruments connected to the a NI PCI-GPIB controller card. This system was working ok until recently, when...
View Articleusing NI interface under Liberty Basic
Looking to control my SPD1168X power supply using Liberty basic as part of automated product test. Is this possible, and how do I do it?I found power supply commands in the manual, but are NI interface...
View ArticleTrouble to communication between Labview and a RS232 Monocrhomator Oriel C130.
I need to read informations from a Monochromator (Oriel Cornerstone 130). The connection between PC and Monochromator is through a USB 2.0 cable. My idea is use the VISA instructions to send some...
View ArticleConnecting Keithley 6517B via RS232-to-USB cable
Hi all, I have been tried to connect the Keithley 6517B to PC using RS232-to-USB cable.I would like to get continuous currents as a function of time from the 6517B. I set up the parameters of both...
View ArticleGPIB USB コンバーター
現在、RATOC製USB2.0-GPIBコンバーターREX-USB220を使用して、計測器をGPIBケーブルで接続していますが、NIMAXのデバイスとインタフェースのツリー上に表示されません。何が要因でしょうか?
View Article