Is it possible to delay GPIB response without causing a timeout?
I understand that a GPIB slave needs to respond within a certain time to avoid a timeout error from the master. However, if I'm the slave, and the command the master has sent is going to take a very...
View ArticlePolling without checking with RQS bit in the SRQ byte
Hello Our machine consists of many seperate hardware parts. One of them is what we call the 'handler'. The handler is connected to an outside hardware that helps in our production.This connection can...
View ArticleKeithley 2612A - How to operate pulse sweep on both channels and get data?
I need some clues how to operate pulse sweep on both channels and get data from Keithley 2612A.One channel sweep is explained in examples of the driver.How to measure and read data from both channels?...
View ArticleAcquire data from multiple (different) instruments
Hello there, it's my first post in the NI forum so i'll try to be as brief as possible.I have 5 or 6 instruments to acquire data and I'm done with using 192832764 different programs to read it all, so,...
View ArticleLong measurements using Keithley 2450 SMU, USB Communication
Hello everyone,I am during my long term measurements using keithley as a part of my system. I perform VdP measurments using my Keithley as a voltage source and current meter. My measuremnets took long...
View Article10401, 10008 errors in Alcor JFTOT analyzer
Hello All,I have a NI PCI-6024E card, working with the Alcor JFTOT device (Jet fuel thermal oxidation tester). When i try run main analyzing program, appears errors "10401 AI/AO group config", "10008...
View ArticleNeed help on USB-8452 Error -301743
When i execute the I2C write program, The error displayed "Error -301743 occurred at NI-845x I2C Write.vi:4470001" .How can i rectify it?
View ArticleSpeeding Up Keithley 2400 Plotting
Greetings, I am using the Keithley 2400 SourceMeter to perform IV curve tracing in real time in LabVIEW 2011. Currently the VI I made creates an array of voltages from the range and step size given by...
View ArticleChoice of laptop
Hello all,I am looking for a laptop to perform data acquisition activities. I found out that processor speed mostly defines the speed of execution of code. So I looked for some laptops, and now I am...
View ArticleConverting a Text Symbol String to a Hex string
Hello, I have a string constant which reads a character of 0 and I want to convert this to a hexadecimal string of 30.I tried to achieve that by using the "Format Value" function. I believe the...
View ArticleSudden 0xBFFF003A VISA error
Hello, Im using a Chroma Power supply 62000P via USB cable (USB A to USB B), I have installed Keythey IO Suite 18.0 and NI MAX 17.0, NI VISA 15.0 and Labview 2012, I created a program to control the...
View ArticleNI VISA LINUX RHEL 7.2 installation conflicts with CVI Linux Run Time Module
I had installed the LABWINDOWS/CVI 2013 RUN TIME MODULE for LINUX on a RHEL 7.2 Linux system and then attempted to install NI-VISA 17.0 for Linux on the same machine and got many conflicts (see...
View ArticleGeneration of arbytrary wave to generate it by DAQ 6008.
Hello,I want to create an arbytrary wave without the subVI (Simulate arbytrary signal). I would like to create 2 arrays, one with the value of the time, and the other for the values, like the subVi...
View ArticlePXIe Chassis-1075 (NI-MAX configurations have been changed without any known...
Dear all, I am working on NI-measurement system. it is included two chassis, one for receivers (VSA) and the other one for generators (VSG). I am using PCI cable to connect the two chassis. Everything...
View ArticleLabview LIFA Control a BLDC Ctrl via I2C
Hi,as a part of my bachelor thesis is to communicate via I2C with a brushless DC Control, my professor told me to use Labview and the LIFA package to communicate with it. After I programmed some...
View ArticleIdentificacion de puerto con un picomotor driver
Que talQuiero utilizar y controlar pico motores, mediante Model 8753 iPico driver. Utilizo el ejemplo (Application.vi)sin embargo, el programa marca un error 7001 indicando que no hay módulos en el...
View ArticleIsolated analog inputs/outputs
Hello,Anybody knows if there are available an USB DAQ with isolated analog inputs/outputs? I need it because I have to contol an power suply GEN 10-1000, by the DB25 connector, which connector isn't...
View ArticleRTSI cable
Hello Everybody, could any of you tell me what is the impact of adding RTSI configuration to the NI MAX configuration in case I already sharing trigger between the devices in the one chassis as shown...
View ArticleNF5600 A and NF5610B lock-in amplifiers
hi, I was wondering if someone can give me labview drivers for the NF5600 and NF5610 lock-in amplifiers?The NF company was very helpful in saying that they don't have labview drivers for the said...
View Articlecan we configure USB raw device from executable which is built-in LabVIEW...
As of my understanding, USB raw device can be configured using NI VISA driver wizard. http://www.ni.com/tutorial/4478/en/ Above link mentions how to create using NI-VISA driver wizard. But I need to...
View Article