Quantcast
Channel: Instrument Control (GPIB, Serial, VISA, IVI) topics
Viewing all 5690 articles
Browse latest View live

VISA unable to connect in NI Max

$
0
0

Hello!

 

I apologize if this issue is relatively trivial. I am not very well-versed in using VISA. I have searched the forums for this issue and I cannot seem to find my exact issue or any solution that works, so I decided I had to write my own thread.

 

So I have  MKS Mass Flow Controller. It has an ethernet cable coming out of it. I connect this ethernet cable directly into the socket on my computer. I set it up so it has a static IP address. I then tried to follow this guide, and I am able to ping the device from the command prompt, telling me that it is talking to the computer. I then continue with this guide and open up NI Max, go to Devices & Interfaces > Network Devices. I right click and select "Create New VISA TCP/IP Resource..." which brings up its dialog to select how to find the new device. I tried using the auto-detect and it said that "No VXI-11 LAN/LXI instruments were found on the local subnet.". I then tried to do the Manual LAN connection and I put in the IP address that I was able to ping in the cmmd window. I got the following error when I tried this:

 

Could not open a VISA session to "TCPIP0::192.168.2.155::INSTR". 

VISA error code 0xBFFF0011

Insufficient location information or the device or resource is not present in the system. 

 

I feel like it is something rather simple that I am missing, however I cannot figure out what it is. 

 

Ideally, we will have 3 mass flow controllers all with their ethernet cables connected to an ethernet switch and then one ethernet cable going into the computer's socket from that. I would like to be able to eventually make a LabView program to read from all three at the same time, although the first thing to do this is to get them to actually connect so i can use a VISA in LabView. 

 

Thank you so much for any help you can give!


Pin definition of VHDCI for NI PXI-5421

$
0
0

Hi, Could everyone tell me how to find the definition for the 68-pin VHDCI DIGITAL DATA & CONTROL of PXI-5421?

 

Thanks,

Fu

MMC project (coordinate measuring machine)

$
0
0

Hi, my name is Gerardo and I am a student and I want to create a coordinate measuring machine and I want to see if someone could help me to choose a controller for servomotors

NI Visa on macOSX Catalina

$
0
0

Is there a planned upgrade of NI-Visa that will install on macOSX Catalina?

 

-- Rick

Watlow F4 Ramping without Profile

$
0
0

Hi guys, I was wondering if there was a way to use the watlow f4 controller without having to make profiles. I am currently using labview for the controller and able to manually change the set point and pid values. I want to be able to have different ramp rates without making profiles. Is there any modus register that is usable or if any idea on to achieve this would be appreciated. Thank you!

https://first2fitness.com/phen375/

$
0
0

 

https://first2fitness.com/phen375/

 

Phen375

Obviously, the catch isn't to starve or feel terrible while you're utilizing this weight reduction supplement. In any case, this doesn't imply that you can in any case eat whatever you like and get thinner. This arrangement must be joined with the most reasonable nourishment that has been prescribed by nutritionists. Consume Fat: Thanks to an amazing fat-consuming fixing L-Carnitine, which can mirror the HCG, you can change practically the majority of your body's put away fat into the unadulterated vitality. Accordingly, you can consume fat an a lot speedier rate.

 

 

LINX I2C bosch bmp180

$
0
0

Hi, im trying to communicate with bosch bmp180 sensor connected to arduino uno. Right now i'm only trying to read ac1 parameter. Am i doing it right? I have never used I2C or anything similar. 

Looking for Suggestions for an Industrial Controller

$
0
0

Hello,

 

I am looking for an industrial controller or a combination of controllers with all (or most) of the following specifications:

-6 Serial ports for connection to computers, balances, etc
-13 Solenoid drivers to control 12-24 volt solenoid valves (or similar)
-10 Sensor inputs for 19C Honeywell analog pressure or level sensors (or similar)
-3 Stepper Motor drivers for 12-24 volt motors
-3 PWM Motor drivers for 12-24 volt motors
-1-Wire interface to read temperature sensors
-2 Optically isolated inputs to sense voltage or contact closure
-4 CMOS 5 volt compatible outputs
-Remote LED display to show status of the valves
-Audible alarm

 

It would be great if someone can point me toward some options.

 

Thanks you.


IVI Shared Driver

$
0
0

Hi ,

I am trying to use Boonton RF Power Sensor RTP5540 in an automated test setup. When tried to initialize the instrument , came out with the error 1172 (Invoke Node System.Reflection.TargetInvocationException: Exception has been thrown by the target of an invocation. Inner Exception: System.Runtime.InteropServices.COMException: VISA read error <append><b>System.Runtime.InteropServices.COMException</b> in Boon1.vi)

It is possible to read the version from instrument , so it is assumed communication is taking place. Attached is the sample code is attached for reference . Please give your valuable suggestion. 

Labview version 2014

OS - windows 7 (64 bit)

NI MAX-Voltage Output tab is not showing when i press the Test panels.

$
0
0

Hi ,

 

I installed the NI softwares,

1.NI 488.2

2.NI serial

3.NI VISA Runtime

4.NI System configuration

5.NI PXI platform services.

 

But when I am trying to open the Test Panels, it is not showing Voltage Output. Do we need to install any plugin to work?

Please find the attachment.

 

 

 

 

 

NI ENET RS232/4 configuration

$
0
0

I've been trying to configure an ENET RS232 server hub using NI MAX for awhile but I can't seem to find it in NI MAX. I know that its there because I can ping it and receive a response... But I did see this note when searching through the forums about this device:

     ENET-232 and ENET-485

     NI-Serial 14.0 removes support for all NI Serial ENET Interfaces (ENET-232/2, ENET-232/4, ENET-485/2 and ENET-485/4).

 

Does this essentially mean I have no choice but to go to an earlier version of NI- Serial in order to configure the device or access the ports? 

GPIB-USB-HS with RHEL/Centos 6 or RHEL/Centos 7 Linux Driver

$
0
0

Amazed how stagnant information is on this site....

 

What is the latest GPIB driver or beta driver that can support 64 bit RHEL6/7

NI有单总线的通信模块么

$
0
0

NI有单总线的通信模块么?  就像I2C用8541一样

Control a pump via CompactRio

$
0
0

Hello

 

I would like to control a metering pump with a CompactRio. The pump asks for 4mA to 20mA to be controled. I have the NI 9381 module but it seems to provide only +-1mA. Does a module, which can control my pump, exist ?

 

Thank you

 

Marianne

There is no NI-VISA for linux at the download page


Controlling USB6229 through network connection

$
0
0

I have a USB6229 DAQ device connected to a computer via USB cable. I need to be able to control it (i.e set and run measurement tasks) from another computer connected to the same local network. Is this possible? Thanks.

System.MissingMethodException for NationalInstruments.Visa.Session

$
0
0

I am getting the following error in a .NET application running on Windows 10 64-bit

 

System.Reflection.TargetInvocationException: Exception has been thrown by the target of an invocation. ---> System.MissingMethodException: Constructor on type 'NationalInstruments.Visa.Session' not found.
   at Ivi.Visa.GlobalResourceManager.Open(String resourceName, AccessModes accessModes, Int32 timeoutMilliseconds, ResourceOpenStatus& openStatus)

(shortened to remove my application specific methods).

 

I have the same SW components installed on another PC (though Windows 7 32-bit) that is working just fine.

 

I am trying to understand what I might be missing. I looked at the NationalInstruments.Visa.dll in the GAC and the Session constructor is internal, so I am not sure why the Ivi.Visa code is trying to call an internal method in the first place.

 

Has anyone seen an issue like this before?

NI-488.2 Version15.5

$
0
0

NI-488.2 Version15.5 のインストーラのダウンロード方法を教えてください。

NI社のサポートページからはVersion17.6以降しかダウンロードできません。

Version15.5でしか動作しない機器を使用したいためです。よろしくお願いします。

What is the latest NI VISA version that install VISA COM version 5.5

$
0
0

I would like to know what is the highest NI VISA version that install NI VISA COM version 5.5? I have VISA COM version 5.11 but I need VISA COM version 5.5 to develop some custom drivers.

TTI AWG TGA 12104 automatic Setup files

$
0
0

Hello,

 

I am using TTI AWG TGA12104 waveform generator and I have created some 10 setup files which has different waveforms with different amplitudes. I want to run all these setup files at a certain time interval. There is no provision to do it with usb connection or any other connection. So I thought of changing the c code which was given in VC6 folder of USB/Examples but I am not able to run the executable which has been produced at the end. So i thought of finding a way around using labview. Can anyone help me find a way of running all those setup files continuously using labview?

 

Thanks

 

Viewing all 5690 articles