Reassemble bit with VISA Labview

$
0
0

Hi,

I've problem with receiving data in Labview.

My receiver data is xbee and my transmitter data is xbee using arduino. I want to transmit analog read from arduino using xbee to another xbee (connect to labview). since, analog read from arduino is 10 bit and xbee only can send 8 bit, so I programmed my arduino to split the data into 8 bit and 2 bit in an array then xbee start to transmit the data.

The problem is i need to reassemble my data from 8 bit and 2 bit into 10 bit in Labview,

I'll attach my VI and arduino Code, thanks

 

 


Connect SCXI1000-chassis to PC

$
0
0

Hello,

 

currently we have an SCXI1000 connected to a PC with a PCI 6024E-card by means of a multifunctional cable (SH68F-68F-EPM). The PC must be replaced and I fear the PCI 6024E will no longer fit in.

How can I connect the DAQ to the PC? Is there for instance a USB-version, or a USB-"SH68Fcable" converter?

 

Thanks for any support,

Hans

Communication problem between measurement acquisition USB device (Non NI) and Labview

$
0
0

Hello,

 

I’m working on an instrumented motorcycle with an acquisition under Labview.
But I’m having trouble with one of the instruments, it’s an inertial power plant equipped with a GPS.
The brand is XSENS type is mti-G-710. For communication, it is equipped with a USB socket.
The instrument is well recognized on the WINDOWS device driver, all drivers have been installed.
I manage to obtain measurement acquisitions via the manufacturer’s software.
But the instrument is invisible under Labview. I even found a Labview project exactly matching this instrument.
But the problem does not come from VI: Under NI Max, the instrument is not recognized.
But the VI crashes in the OPEN VISA block, because no physical input is present, I tested all the COM and ASRLXX::INSTR ports....
Have you ever encountered this kind of problem?
I’m in the middle of a solution.

 

Thank you for your help

 

Pascal

Locating GPIB-USB-HS Driver

$
0
0

Hello ,
I have a measurement interface that had been developed on labwindows and it had created a distributor. I have the interface but I'm not the source code.
Before that he communicated via GPIB -GPIB.
But I have a PC that I want to communicate GIPB/USB with my spectrum analyzer.
Think about it with the GPIB/USB  of national instrument it will work thank very much

Temperature measurement USB6343

$
0
0

I'm measuring the cooling of a metal part with 4 type K thermocouples connected to the USB-6343 in the SignalExpress software, the signal registered oscillates too much, hence the temperature measurements have noise. I don´t know if it's a configuration problem or electrical noise. Any recommendation to avoid this oscillation problem?

LINX I2C bosch bmp180

$
0
0

Hi, im trying to communicate with bosch bmp180 sensor connected to arduino uno. Right now i'm only trying to read ac1 parameter. Am i doing it right? I have never used I2C or anything similar. 

Agilent Technologies Turbo-V 750/850 ag Rack Controller Driver

$
0
0

So I'm looking to connect a Agilent Technologies (now Keysight) Turbo-V 750/850 ag Rack Controller to LabVIEW 2019 through serial. However, after emailing agilent, I found that no driver existed. After some searching around on the web, I hit a dead end. I'm just wondering if anyone out there has already created a driver for this technology or a driver for something similar that I could work off of. I want to note that I have very little experience with LabVIEW and any help would be helpful.

Windows 10 "creating" multiple addresses for GPIB-USB instruments

$
0
0

Our LV programs stops working after a few days. GPIB-USB connecton to the instruments is lost. KeySight Connections shows multiple GPIB addresses for each instrument (e.g., main address is "GPIB::23::INSTR", and several sub-addresses are shown as "GPIB::23::0::INSTR", "GPIB::23::1::INSTR, "GPIB::23::2::INSTR, etc.). It appears that a unique sub-address is being created for every user that logs onto the PC, which has Windows 10 OS. This does not occur on the earlier versions of Windows OS, so it may be something new for Windows 10. However, this does not explain why the program loses connection after some time. I thought it may be because the programs are addressing a specific GPIB string (i.e. "GPIB::23::INSTR"), which may become invalid for next user that logs on (i.e., sub-address created as "GPIB::23::8::INSTR"). To test this theory, we tried assigning an alias for each main address. First, we disconnected the GPIB-USB cable, removed all of the GPIB addresses and sub-address in KeySight Connections, refreshed, and then reconnected the GPIB-USB cable. After refreshing KeySight again and waiting for the main GPIB addresses to reappear, we then assigned a unique alias to each of the main GPIB addresses, and replaced the GPIB address strings with the alias strings in the LV programs. The programs worked as usual, no problem. Next, another user logged onto the PC, and the sub-addresses were created as expected, but the alias strings did not get carried forward to the new sub-addresses (e.g., alias "blue" was assigned to main address "GPIB::23::INSTR", but it did not automatically get assigned to the sub-address "GPIB::23::8::INSTR" created by the OS). However, the programs continued to work ok. Next, we asked several other employees to log onto the PC. And, as expected, new sub-address was created for every user the logged onto the PC, and the programs continued to work ok for every user. Seems like problem solved, but I am uncertain that we actually "fixed" the underlying issue. Has anyone else seen a problem like this? Does anyone know why Windows 10 is "creating" sub-addresses for every user?


LCR METER with prologix

$
0
0

im trying to measure the value of resistance on the LabVIEW using LCR Meter 1730T Quadtech with the Prologix GPIB/USB the when I run the program I get the error Old VISA Open in 1730 Series Initialize.vi->1730 Series Example.vi and I don't know how to fix could anyone help me please ?

 

and other thing the "source" element of the "error out" cluster simply set to this value with the "status" element set to false ? how I fix this too ?

PXI-4060, PXI-5102 calibration

$
0
0

What equipment and software is needed to calibrate PXI-4060 DMM and PXI-5102 SCOPE, both installed in a PXI-1010 chassis?.

We need to be able to do in-house calibration.

keithley 2401

$
0
0

hi all, do anyone have Keithley 2401 SMU LV drivers to read Voltage vs time and current vs time.It is not there in either labview instrument drivers or keithey webpage.

Thanks in advance..

Agilent 34461A Timeout Error

$
0
0

Hello, 

Im using an Agilent 34461A and connecting to my laptop via USB and using Labview 2018 on a Windows 10 machine. I downloaded the Plug and Play driver and using the example code for single measurement I timeout when I query. In NI max the same result. I downloaded the IVI driver and attempted to use it with my device. Timeout error after initial connection with NI Max and the example code. It is only when I restart the DMM with the USB connected that I can query successfully.  There is a Windows 7 device running Labview 2017 that interfaces perfectly with the PnP driver and runs on initial connection with this device and I have unsuccessfully taken the driver from that computer and try to use it on mine.

 

I also have access to an Agilent 34405A that I use with a PnP driver on my machine that I have no problems with. I have looked across the forum and tried everything I could find concerning this specific device with no luck. I would ideally want the PnP driver to work but can also use the IVI driver. My USB ports are not turning off and stopping connection with the DMM. Any help would be greatly appreciated. I have attached a file with I/O traces and successful query results. 

 

Note: I am using NI Visa 18.5 and the most recent PnP and IVI for Labview drivers for the Agilent 34461A

Also, recently I would connect after restart and it would go into a simulate mode where on measurement query it

would output very large values.

 

I would appreciate any help as to why this may be happening and thanks in advance

Connecting an instrument using GPIB-USB connection.

$
0
0

I am a rusty LabView developer. I have a GPIB instrument ( Ruska 7750i ) and I am currently using a GPIB to USB convertor. 

First I am having trouble downloading the driver from the NI download site for the Ruska 7750i. I get a " network error " message.

Any help with that ?

 

Please advise, thank you.

NI VISA and Arduino interface

$
0
0

We are facing issues when transferring Integer values from Labview to Arduino via VISA over a serial interface. The values being sent are real-time. How to read values simultaneously in the arduino code.

Connect Spectrum Analyzer RSA306 to LabView

$
0
0

Hello,

 

I am trying create a VI that connects a Tektronix RSA306 (via USB) to my PC, for the purpose of feeding in and correlating data on my PC. 

 

I have downloaded the Tektronix DLL driver, but I cannot find the correct blocks to 'initialize' my spectrum analyzer for the connection in LV. I have looked online for possible examples using a physical spectrum analyzer but no luck yet. How can I initialize it?

 

Thanks in advance. 


Matlab with NI GPIB-USB-HS on Mac OS X 10.13.6

$
0
0

Hi,

 

I am trying to start at GPIB connection to my Keithley 2400 source meter using a NI GPIB-USB-HS converter on Matlab r2015b. NI Max indicated that the device is connected. However, I keep getting the following error (see attached image): "The specified  VENDOR adaptor could not be found."

 

Any ideas on how I can solve this issue. 

 

Thanks!

GPIB-USB-A Driver for Windows7 32bit or 64bit

$
0
0

Hi,

    I have a GPIB-USB-A card, I want to use it in the windows7 32bit or 64bit. Who can send us a NI-488.2 version which supports the GPIB-USB-A card and supports the windows7 32bit or 64bit operation system. The latest NI-488.2 ver19 don't support the GPIB-USB-A card.

   Thanks, my email is support@bost-ltd.com.

How to send only hexadecimal values as input through serial port ( com port ).

$
0
0

I want to take input from user through keyboard and send the same via serial port. Here how can I pass only hexadecimal values.

Why is the data displayed when "Highlight Execution" is turned on?

$
0
0

Dear Sir,

When I use the PIC CPU to transfer data to LabView via RS232, Why is the data displayed when "Highlight Execution" is turned on?

擷取.JPG


How to solve it?

The full vi program is attached in the attachment.

Thank you very much.

Hung-Jin Chen

GPIB -USB adapter price

$
0
0

Hi,

We want GPIB-USB adapter for our HPLC machine,

Can you please send us quotation to erp.tpr@aartidrugs.com id.

Thanks..