USB-8502 Legacy Compatibility
Hello everyone, Apologies if this is posted in the wrong location. Our computers run on a Windows XP operating system due to using Melles Griot Nanopositioning software (MG17, MelHost V5.41). This...
View ArticleNI Max cannot find GPIB device
HiI have installed NI MAX and it worked well with Agilent USB/GPIB interface 82357B ( I also installed Keysight IO libraries suite to driver it). Then I installed Labview community version for some...
View ArticleGPIB-USB-HS - Win 10 - Driver delays the cyclic commands longer and longer
Hello,for many years we have successfully used the USB-GPIB adapter from NI ("NI GPIB-USB-HS+") under Win-7.Since the recent change to Win-10 we now have the problem that the driver delays the cyclic...
View Articlesimultaneous measurement with two multimeter periodically.
Dear, I would like to measure two DC voltages (~several 10 V) with two independent voltmeters simultaneously.The measurement should be done in every 2 seconds interval for 1000 seconds (in this case,...
View ArticleNI VISA compatibility with OpenSUSE Wicked
Hello, So I work in a university research lab as a graduate student researcher. We have a number of computers running different setups (each with multiple instrumentations hooked up to them) in our...
View ArticlecRIO controller for VISA instrument control
Have a system controlled by a cRIO controller (cRIO-905x). Have a remote panel with a GPIB device in it. Since cRIO doesn't support GPIB with 488.2 (only VISA), then I would like to use a RS232-GPIB...
View ArticleNeed help with Midwest Flex Cable Wedge
Hello all,I have a Midwest Flex Systems CableWedge I am using to do a very simple timed read on a digital indicator. I have done similar systems before with different hardware with no issues but I am...
View ArticleLabVIEW VISA Test Panel unable to communicate with Chroma ATE 61504
Hello,I meet some problems using VISA Test Panel in NI MAX to communicate with Chroma ATE 61504 AC source. I am using RS-232C serial port and I configured the port setting in NI MAX exact the same as...
View ArticleCant add my RMX 4102 power supply to PXIe-8881
Hi there, I am trying to add my RMX 4102 power supply to my PXIe-8881 under network devices, however when I try to add network device I get the following message This is strange because I have...
View ArticleProblems to initialize/read Power Meter
Hello, for our EMS measurement place we have a new PC, the rest of the seutp stays the same.After installing all drivers I still get error messages regarding the power meter. Please find the detailed...
View ArticleNILinux2022Q1DeviceDrivers/ni-rhel8-drivers-2022Q1.rpm
I downloaded and installed the NILinux2022Q1DeviceDrivers/ni-rhel8-drivers-2022Q1.rpm archive on a Red Hat 8.6 pc.I wrote a small c program to communicate with a GPIB instrument and it executes as...
View ArticleUsing LaBview to make a signal generator generate a waveform with...
Hi How to use LaBview to output a continuous sine waveform, and add a pulse wave when the sine wave stops outputting, and it can be repeated periodically? Thanks xia
View ArticleGPIB timeout during ReadByteArray
Hey all, Trying to set up a new testing set up for LIV measurements. I have a Keithley 2400 SMU and a DMM 6500. Communicating with a GPIB-USB-HS (but have also tried the +).It can write commands fine,...
View Articlecan not recognize the PCIe after restart
can not recognize the PCIe in “Measurement & Automation explorer” after restart
View ArticleVISA Connection with Non-NI Hardware
Hi all, I am having some connection issues with a piece of hardware which I have. I will try to be as specific as I can but due to the nature of what it is, i'll have to keep the hardware vague. I can...
View ArticleAdd GPIB Ethernet Device Not In Max Under Network Devices
I have a TestStand deployment that I built and I am trying to get running on the target machine. What is holding me up this time is MAX not showing me under Network Devices --> Add GPIB Ethernet...
View ArticleOne ethernet address for all?
We have a big system with several bus, talking to many units and racks. We still use GPIB on some older units. We now have newer versions of the units that have ethernet and we were considering...
View ArticleNI-VISA - USB devices not recognized - Linux (Ubuntu 20.04 LTS kernel 5.15)
Hi all, I'm trying to interface with a USB Test and Measurement device. In the end, I want to be able to interface with the device from my own C++ program in a Linux environment. However, I'm unable to...
View ArticleWrite String to Serial port
The goal is to select a string (button) to send to a RS-232 instrument using a USB to serial converter to be run on any PC from an EXE file. The front panel buttons will select which string to send and...
View ArticleNI 488.2 libnipalu failed
I have installed the driver NI 488.2 successfully, but when I open the application, I got the following error constinuosly: "The attempted operation failed. libnipalu.so failed to initialize. Verify...
View Article