USB-485 and Windows 10

$
0
0

Hi,

 

I have a USB-485 which I have use on a Windows 7 64-pc with no problem. But when trying to install it onto a Windows 10 pro pc then NI MAX indicates that windows has no driver for the device.

 

Capture.PNG

What could be the problem?


scanning for serial port using Labview

$
0
0

My system is Window 7 32-bit

Labview 2011

I have a usb to serial device. After the device is plugged into the computer, window will show a usb-serial device. Without going to the device manager, is it possible to use Labview to scan to see what COM number the device is enumerated as?

I can use VISA  find resources to check the COM port. But if i have multiple COMs on the PC, how do i know which one is the one from my device?

thanks.

 

Communication between DG535 and WinSpec

$
0
0

Hi,

I am trying to connect DG535 to Winspec.

When doing it, I have a pulsed source of 25o msec and a delay of 750 msec.

If I use repetative method.

What should be the exposure time, Gate width and Gate Delay.

Can any one help?

 

Thanks

Drivers of DG535

$
0
0

Hi,

When ever I connect the DG535 to Winspec, I get a Blue screen on my PC.

What does this indicate.?

Thanks,

San08

 

Driver for HP 3478A digital multimeter

$
0
0

Im trying to connect this multimeter to labview, and Im having problems. Im trying to measure the DC voltage, and to show me the measurements in labview. Could someone help me.

PXIe-8135 GPIB Scan for Instruments disabled

$
0
0

Hi,

I want to connect an electronic load to the PXIe-8135. I bought a Micro D cable and connect the load . When I open the Measuremanet Explorer, I open devices and see the PCI-GPIB. The self-test was successful. But the button "Scan for instruments" is not available. It is grey and has no funktion. Has anybody a solution? The settings from the PCI-GPIB are: GPIB-ID=GPIB0; Primary Adress 0; Secondary none; Timeout 13(10s); System-Controller and Autopolling are enabled; End of write enabled; Cable HS488 0; Parallelpoll 0 (2µs); Bus-Timing 2 (500ns).

regards

run NIvisaic failed on openSUSE13.1, the error occurs : Can't load library /usr/local/lib/liblvrt.so.14.0

$
0
0

Install information:
  OS vsersion : openSUSE 13.1
  NIVISA : nivisa-15.5.0
  NI4822 : NI4882-15.1.1

 

When I run the command "NIvisaic",the error occurs as following :

 

Can't load library /usr/local/lib/liblvrt.so.14.0
libXinerama.so.1: cannot open shared object file: No such file or directory
To download the LabVIEW Runtime engine, go to
http://www.ni.com/rteFinder?dest=lvrte&version=14.0&platform=Linux&lang=en

Agilent E3663A VI for constant current mode

$
0
0

Does anyone have the application VI for setting up the constant current mode for Agilent E363X Series Power Supply since I have to set the power supply to run in the constant current mode?

I would be most grateful if you could present me the VI's at your earliest convenience.

Thanks a lot,

James Ouyang

email: xiaohong_ouyang@arxtron.com


Error -1073807360 occurred at Property Node (are 8) in VISA Configure Serial Port (Instr).vi->practise.vi

$
0
0

hi,

    I want to write data from labview to my micro controller(PIC18F87J50),but i am getting the above mentioned error,here i will attach my labview code and mcu code ,please go through them and help me with a solution

environment

$
0
0

why don't NI think about the environment why spill a lot of energy to download 8GB if you only need a driver of 10 MB i dont know how many NI users are forced to download 8 GB whil the only to need to update a small driver but its a waste of network traffic energy

Keithley Pulsed 2602a

$
0
0

Hey Experts/All 

 

I am relatively new to using the LabView coding for Keithley 

I am looking to build LabView VI which can pulse a source function and measure a function. 

Any VI to build on while be useful. 

 

Thank you.

Installation abort of NI 488.2 in CentOS

$
0
0

I already have installed NI-VISA on this machine, which is running CentOS 7.

 

I have downloaded NI 488.2 from here: http://www.ni.com/download/ni-488.2-3.2/4916/en/

and am running the ./INSTALL script as sudo.  I receive the following error message (after passing the license agreement etc.):

 

NI-488.2 version 2.9.1f0
is about to be installed using rpm at /usr/local/natinst

Would you like to continue? [Yn] 

Installing NI-488.2 version 2.9.1f0...
Pre Installation .
Post Installation .
Skipping nikali-2.3.1-f0.noarch.rpm installation, same or newer already installed.
Skipping nipalki-2.8.1-f0.x86_64.rpm installation, same or newer already installed.
Error: Installed package ni-palni-pal provides nipali, but does not mark it as obsolete.

Installer is aborted.

How can I proceed with this installation?

 

TNT4882

$
0
0

Now I am using TNT4882 in one-chip mode,when  sending  the SOFT RESET command(0x22) to the register CMDR, I found that the   HALT, STOP bits are not set. Also,the REN bit remained to be set  when writing(0x00)  to BCR register,I didn't know why , Looking forward to your help,thanks.

Reading number from instrument without the driver.

$
0
0

Hi,

 

I am using the instument sr830, a lock-in amplifier via LabVIEW. This instrument uses IEEE-488 port, aka GPIB.

Unfortunately, my LabVIEW version is too low to be supported by sr830 driver available here. 

So I think I need to figure this out only with the built in vi`s. 

All I want to do is just reading off the numbers on the lock-in amplifier screen. 

There are two channels for the instrument. I just want to tell Labview to read the number from which channel. 

This looks very easy but I have been stuck for more than a week now.

To be honest, I don't really know what I should do.

 

Any help will be appreciated, thank you.

instrument HP3458A

$
0
0

je suis a la recherche de l'instrument pour CVI d'un HP3458A (HP3458A.FP)

I am looking for CVI instrument of a HP3458A see HP3458A.FP


visa installation on opensuse 13.2

$
0
0

Hi,

 

I am currently trying to install the visa driver 15.5 on opensuse 13.2 as it is supported by ni.

I installed the kernel sources, gcc, make etc.

And now when I am executing the ./INSTALL script, I get the following message:

Checking required install tools...
Checking installer tool versions...
rpm 4.11.3 can be used with a default installation path
tar 1.28
Checking dependencies...
glibc 2.19
Unpacking install files to /tmp/nivisa-15.5.0f1.install...

 

max: ERROR: Kernel source does not appear to be installed for the 3.16.7-35-desktop kernel.
max: ERROR: Installation of the kernel-source package for kernel 3.16.7-35-desktop is
max: ERROR: required to continue this installation.
This document contains the following licenses:
1. National Instruments Software License Agreement (Linux Driver Software)
2. IVI Foundation License Agreement

 

when I type uname -r:

3.16.7-35-desktop

 

ls /usr/src/ :

linux linux-3.16.7-35 linux-3.16.7-35-obj linux-obj packages

 

ls /lib/modules:

3.16.6-2-desktop 3.16.7-35-default 3.16.7-35-pae
3.16.7-35 3.16.7-35-desktop 3.16.7-35-xen

 

if i continue the installation and try to start the nipal service I also get an error:

sudo /etc/init.d/nipal start
error: /lib/modules/3.16.7-35-desktop/kernel/natinst/nipal/nipalk.ko not found
error: Please compile and install nipalk.ko by running
error: updateNIDrivers

 

and

 

sudo /usr/bin/updateNIDrivers
nikal: ERROR: Error locating kernel sources for the requested kernel version (3.16.7-35-desktop).
usage: ./updateNIDrivers [--no-prompt] [kernelVersion]
kernelVersion
Specify the version of a kernel installed on the system.
A /lib/modules/<kernelVersion> directory should exist for each
kernel installed. The currently running kernel is the default
for ./updateNIDrivers if no argument is provided.
Run 'uname -r' at the command prompt to find the version of the
currently running kernel.
--no-prompt
runs in no prompt mode. Useful if calling this script from
another script. Messages are still printed to the screen and
the return value can be checked for status.
--fast
use fast shortcuts to determine whether modules need to be rebuilt.

 

Does somebody knows how to deal with this ?

 

2 USB Cameras on same bus

$
0
0

Hi.

 

I have 2 usb cameras which work fine when plugged into seperate USB busses. I want to use multiple cameras with a usb hub and to lower the frame rate.  The default frame rate is 30 fps and the cameras work fine independantly at this speed. To try to get 2 devices working I have opened 2 NI-MAX windows. I have changed the video mode to 288x288 YUY2 7.5 fps. This is a substantial reduction. I do the same for the other camera in the other NI-MAX window but I get a timeout error 0xBFF6901B when trying to preview the second camera. Surely this should be able to handle both devices with the lowered speed.

 

Is this possible or does the bus not allow more than one camera device?

 

Thanks,

 

Mark.

Communication with Omni-300 Grating Monochromator by USB port

$
0
0

Hi everyone,

 

I'm new here and I'm beginner in labview, so my question will sound wierd to you. I'm trying to do program which will communicate with with Omni-300 Grating Monochromator (from Zolix company) by USB port. I have commands to communication with device. I did simple program for test with command "Hello" which I put below:

main.PNG

initialization.PNG

hello.PNG

So I send command "Hello" to monochromator and the device should return word "OK", but I haven't got anything. Only I get error code: 1073676294. I don't know what is wrong. I've tried to change CR and EOL but it didn't help. Below I put what is written in instruction about command "Hello". 

command_hello.PNG

Any suggestion what is wrong?

Any suggestion will be realy appreciated

 

Best,

Ernest

Tektronix AFG 3102

$
0
0

Hello.

 

With the help of another user i've implemented this code.

 

When i first run after rebooting the the tool it appears the error shown in picture 1.

 

Then, when i try to comunicate it appears the error in picture 2.

 

The strange thing is if i double click my Standard Wave Form.vi and change values into that vi it works ...

 

Also i post my code in picture 3.

 

Best regards.

 

 

visa.NS does not see termination character

$
0
0

Due to our remote test controllers running Windows XP, and the instrument being controlled has no Win7 drivers, I am writing x86 code on an XP machine.

 

I am attempting to control an instument using TCPIP/Socket

 

Outgoing commands work. But, I am getting a timeout when reading or query.

 

Telnet works as does NI-MAX

 

I am writing in VS2005 using visa.NS message based (mbsession)

 

mbsession.TerminationCharacterEnabled = true;

mbsession.TerminationCharacter = 13;

 

Have tried both orders...

 

NI-VISA 5.3

 

Thanks