Communication with LPM01A power consumption measurement board

Hello, ST offers a power consumption measurement board which can measure very small current: 1nA .. 200mAX-NUCLEO-LPM01A:  https://www.st.com/en/evaluation-tools/x-nucleo-lpm01a.html My Question: Is...

View Article


NI-488.2 not recognized by Visual Studio C++

I originally posted this in the NIPM forum but I was told it would be more appropriate here.  I'm attempting to run the power step up example code included with the NI-488.2 package, however whenever I...

View Article


MPC with cRIO 9064 for control application

Hello, I am working with cRIO 9064 and using it to command a NI stepper motor as a part of model ship setup. I have presently implemented PID and LQR controller in real time with scan engine. Can...

View Article

Testing connection to MD-CC4 USB RS422 for a mdrive stepper motor made by...

I am new to LabView and I am trying to fix a script that hasn't worked in over a year at my university. I have a stepper motor that I would like to control via LabView. The LabView version I have is...

View Article

Tektronix MSO 5 Series is communication error

Hello . I programming Visual Studio 2015 c# with Tektronix Scope MSO 5 Series I send and receive data through the oscilloscope and LAN communication. After about a day of testing that loads data into...

View Article


NI-VISA driver wizard problem with USB 3.0 USBTMC device

For SS device, bMaxPacketSize0 = 09h (2^9 = 512B). However, NI-VISA failed to detect SS device and showed error that this value should be 8, 16, 32 or 64 bytes.

View Article

NI 9269 Module Detection Issues

Hello, we are having some issues with some NI modules, we have been calibrating multiple DAQ modules using CalExecutive 3.6, we connect the modules via USB with a NI-cDAQ-9171. It looks like every...

View Article

Instrument Detection Issues

I have an HPLC instrument connected via an NI GPIB-USB to the computer and am getting issues on my HPLC software.  I tried to troubleshoot and I can find the device in NI Max (it pops up whenever I...

View Article


781524-01 still available

https://knowledge.ni.com/KnowledgeArticleDetails?id=kA00Z000000P7bUSAS&l=en-US Is this cable still available? Does anyone have one to sell? Thanks!

View Article


In my IVI switch driver created in LabWindows/CVI, how do I set certain...

For an IVI switch driver created with the "IVI Instrument Driver Wizard" capability of LabWindows/CVI (2017) accessed through the "Tools -> IVI Development... -> Create IVI Specific Driver..."...

View Article

Image may be NSFW.
Clik here to view.

Download data/data logging Keithley 2636A

Hi, I have a GPIB-HS+ cable connected to a Keithley instrument, 2636A. I am trying to 1. download a data trace from the instrument buffer. 2. do some real-time sampling from the instrument to LabView...

View Article

Image may be NSFW.
Clik here to view.

Keysight DAQ970A not found by NI MAX

The DAQ used to be recognized my MAX and found in Labview, but after a restart of Labview the DAQ disappeared from both NI Max and Labview but Keysights own software still works (BenchVue and Keysight...

View Article

configuring keithley 2460 with labview

Hi All,I'm trying to configure Keithley's 2460 source meter with LabVIEW.I can find the instrument in LabVIEW but if try to configure that, I can't find the model.I doubted that Keithley 2460 will work...

View Article


Image may be NSFW.
Clik here to view.

Request for Packaging information

Hi,This is Prashant Dhavale from Flex.We are currently working with one of our manufacturing plant to collect Pin 1 orientation, Tape pitch and width, Package for below MPNs.Site: Senai medical...

View Article

How to send commands and data upon request

Hello guys, I have gpib-usb-hs+ module and I am required to send the following commands and data in the following sequence:MLA18{DATA} (6 BYTES)UNLMTA18{DATA} (5 BYTES)UNT I need this exact sequence...

View Article


Siglent 1202X-E VI Building Tutorial

Ok. So I want to make a VI that can record data from my oscilloscope and store the waveform data into a txt file. Preferably with only numbers and nothing that would make Matlab annoyed... not sure if...

View Article

RHEL 7 drivers for PXIe-8234, PXIe-5413 and PXIe-8238

Hi. Could someone tell me, please, if I be able to work with PXIe-8234, PXIe-5413 and PXIe-8238 on RHEL 7 OS? Didn't found any information about compatibility of this modules and linux.

View Article


Cant load GPIB-32.dll

I am trying to connect by NOVOCONTROL Impedance analyser using a GPIB-USB cable. I have also installed GPIB-488 version 2.3. But i am getting the error saying "cant load GPIB-32.dll". I am a...

View Article

Accessing VI_PXI_BAR0_SPACE of PXI device

Hi,I am trying to read/write VI_PXI_BAR0_SPACE of PXI device using with VISA library. Here is sample C code how read data from BAR0 memory. ViStatus res;ViSession defaultRM, vi;ViUInt32 oldData,...

View Article

Daqmx causing STM Virtual com port to disapear from device manager.

I have come across an issue where by installing  Daqmx to run a USB-6001 device is causing a connected (USB to serial) STMicroelectronics Virtual com port to disappear from device manager. If i...

View Article
Browsing all 5566 articles
Browse latest View live


<script src="https://jsc.adskeeper.com/r/s/rssing.com.1596347.js" async> </script>