Issue setting up rs232 communication
I have been having trouble setting up rs232 communication using the port on an sbRIO9607 (the process should be the same as for a cRIO). I have a program that works fine on the computer but when i try...
View ArticleAdd gpib-enet\100 with python
Hi, I'm trying to create a python program that gets a gpib-enet ip and adds it.It should be similiar to the "gpib ethernet wizard".I can't find a way to do it programmatically without actually lauching...
View ArticleUnable to create create INF file for third party USB device
Hi,I'm trying to establish usb communication to a microchip controller,which has its own drivers built on WINUSB.dll. I've tried to create an INF file on NI-VISA but I get the product discriptor...
View ArticleAcuity Laser AR1000 Serial communication
Hi,I am hoping someone has got one of these lasers and is using with Labview and would be kind enough to share their VI, I am a novice to Labview and struggling with basic communication and VISA...
View ArticleAgilent 33220 Arb Waveform remote control issue- Error -220, Data out of range
Hello, I am controlling one Agilent 33220A through one CVI application using the USB port, thanks to the API :Ag33220_InitWithOptions,...
View ArticleIs big and small endian still around?
Hi fellow members; Linking with the modern days gpib-32 or the ni488 library/obj, do ones still need to be concerned with the small and big endian conversion in board level or device level calls or...
View ArticleDriver for Cole-Parmer Pump 775211-70
Hello all, We are looking to control a Cole-Parmer Digital Gear Pump Drive (Model #: 75211-70) for an automation project. The pump will be controlled with LabView (Version 15.0.1) to turn it off or...
View ArticleRAW shows up but not INSTR
Hi all, I'm using LabVIEW 2015 on a Windows 10 machine. Previously had a program working just fine, it would connect to the NI-VISA USB Instrument and display a continuous graph, but when I came in...
View ArticleNI-Serial 15.0 Installation Induced Havoc
Attempting to use the NI-USB USB-to-RS232 adapter, I downloaded NI-Serial 15.0 and installed the software suite. Upon restarting, I received a Windows Genuine Advantage error stating my copy of Windows...
View ArticleIMAQdx Internal Error
Hello! I'm quite new at this, and not very familiar with this software, so pardon my ignorance if I'm asking a silly question. I'm using the Measurement and Automation Explorer (NI-MAX) software to...
View ArticleRead data from 2 serial port and forwarding to single port
Hi, I am trying to write a vi which can read serial data from 2 com ports and write to the single port one by one.For example: Read VISA 1 o/p--- > 1 string Read VISA 2...
View ArticleHow can I control a Lecroy WaveRunner 6100A?
Hi,I have a Lecroy WaveRunner 6100A (the OS is Windows XP) and I'm struggling to connect it to my computer in order to acquire data with Labview 10. I have no GPIB on my computer; I downloaded the...
View ArticleFraming Error with PCI-8433 and MAX at 921600 baud
We can successfully communicate with an instrument using the PCI-8433 interface card with the Microsoft VB.NET COM control. But we get a framing error if we try to read more than 44 bytes with MAX at...
View ArticleGetting the data from HMR3500 Magnetic Compass Module
the hmr-3500 is placed b/w six BLDC(brush less dc motors).when the motors are off it gives us the value of 200(azimuth) and when in on state the value shifts at 220.and when again it is off it gives us...
View ArticleHMR3500 Magnetic Compass Module
1-another problem that i am facing is i am unable to compensate/isolate/deviate the HMR-3500.2-when the value of azimuth is between 270 and 290 it gives us two values either 270 or 25.kindly guide me...
View Articlespectrum one CCD3000 needs some kind of post processing?
hello,i used the labview drivers set to adquire a spectrum from a CCD 3000, no matter monocromator position or slit aperture i always get some kind of this. my question is, this signal requires...
View ArticleProblem with USB-3488A
I have a probleme with USB-3488a and labview.with the adlink driver the usb-3488a work bu i not see in n-max, i have a lastest version of labview and Ni-maxIs it anybody have the same problem ?
View ArticleXY-Stage control and xy-coordinates
Hi everyone,I'm using a 2-axis linear stage from Zaber technologies, and I want to be able to input xy-coordinates to dictate where the stage moves. The problem that I'm noticing is that the stage...
View Articleproblem whit initializing and updating the PCI-7354
hiI have a pci 7354 motion controller, connected to tribometer nanovea, when i wanted to initialize it and update it, i have had errors i can't solve them.here is some pictures to help you understand...
View ArticleLove controls 16b communicate with labview 2012
Hi, I need to investigate the way to communicate temperature controller 16b (Modbus) with Labview. I have looked at many topic in forum and found out the Modbus library...
View Article