64-bit Labview 2013 Ni-845x = ?????

Rediculous.... If I have the following setup: - Windows 7 64-bit- Labview 2013 64-bit- NI USB-8452 What driver do I use???????  v2.1.2 is 32-bit only... v2.1 coverd 64-bits but not for Labview 2013,...

View Article


viFindRsrc returns nothing using VISA 14.0.1

I have software that uses the following method to identify PXI card addresses in a PXI chassis. viOpenDefaultRM (&rm);viFindRsrc (rm, "?*", &vi, &retCnt, desc);viFindNext (vi,...

View Article


HP 8596 Spectrum Analyzer Data Collection

 Greetings,  I am doing a project to read data from "HP 8596E (Agilent/KeySight 8596E)" through MIL-STD-461E, CE102 standard. The program should plot the spectrum as well as save it to a spreadsheet....

View Article

Capturing FFT waveform from Agilent Oscilloscope and displaying on LabVIEW...

Using LabVIEW I was able to command the function generator to output a signal. I then commanded the oscilloscope to capture the waveform and plot the FFT. I now want to take the FFT waveform displayed...

View Article

NI PMC-GPIB on Linux kernel version 3.11.10 (Fedora 20)

Can the NI PMC-GPIB run on Linux kernel version 3.11.10 (Fedora 20)? The linux OS is a hard requirement. Thanks 

View Article


unable to load gpib-32.dll when running the visual basic 2008 program

I installed NI-488.2 into my PC, window 7 64 bit OS.In the program >> project> add reference>.NET, I successfully add the NI.4882  into my visual basic  program.By the way, this program...

View Article

HP E3631A loses connection with Labview after extended use

Hi all, I have an HP E3631A connected to my computer using an RS232 to USB adapter and controlled with a Labview VI. When the VI is started it controls the power supply nicely, but after a while...

View Article

Eurotherm 201 controller error message

Dear colleagues, The error message EE.er came up in the controller (Eurotherm 201) display and I cannot operate my Carbolite furnace. Up until then, I was using it at low temperatures (300C) for...

View Article


No leading command

Hello, I am trying to connect my Power Supply(Hameg 8142) over GPIB with my Computer.I have connected everything right, but when I try to ''Scan for Instruments'' on the Measurement and Automation...

View Article


NI MAX Not Found Agilent 53131A

I am currently using GPIB-USB-HSInstallation software are:1. NI-488.2 14.0.02. Keysight IOLibSuite_17_1_19313NI MAX can not found Agilent 53131A Anything missing? Thanks

View Article

serial port reading

dear friends how can i read and write data on serial port meanwhile vi is running elapsed time function for 22 seconds i am sending command during elapsed time but it is not respondingthanks 

View Article

Re: TNT4882 Chip

How to resolve the hang-up of TNT4882 after write-transferhttp://forums.ni.com/t5/Industrial-Communications/How-to-resolve-the-hang-up-of-TNT4882-after-write-transfer/m-p/1287848 can you hlep me about...

View Article

MAX error insufficient location information or the device is not present

Hello,    We have been getting this error once in a while on our test system.  (See attachment)  Our system is running Windows 7, MAX 5.5.0f0, TestStand 4.2.1 and LabView 2010 SP1.     To get the error...

View Article


GPIB-RS232 Converter

Hi: I have the following setup. Advantest Programable Voltage/Current Generator's GPIB Port (it is a GPIB Instrument) is conntected to a NI GPIB-RS232 Converter and Convertter Serial Port is conncted...

View Article

remote control EXP TEST RECEIVER by SEE PRO

hello! I have question! Now i am working with ESPI TEST RECEIVER. I must make program for automatic measurement EMC by VEE PRO. I have problem: I don't know how to get data (level: PEAK, AVERAGE, RMS)...

View Article


gpib usb not detecting

Hi, I'm having issues interfacing a Keithley 2400 with a GPIB USB HS adaptor. My Windows 8.1 machine is not picking it up when the adaptor is connected to the Keithley 2400. In addition, none of the...

View Article

Facing Hex 0xBFFF00A0 error in VISA

I am using PXIe 8820 controller. In MAX i want to configure VISA to route the front panel trigger to the backpanel trig lines (TTL0...TTL7 ect).Every time i am mapping in VISA erro occurs as "VISA:...

View Article


Image may be NSFW.
Clik here to view.

Dinamic Inputs requirements to SubVIs

Hi All,I am not an expert on Labview, but recently I adapted some serial protocols created some years ago for an acquisition system.I have two different boards to communicate with, both have their own...

View Article

After installation of Visa runtime my mouse is moving with COM data

I'm sorry, I don't know anything about Labview I'm just using prepared GUIs. After installation of the Visa540 runtime my mouse is moving everytime I get data from the COM1. How can I switch this off?

View Article

PCI GPIB card not indentified

I'm using a PCI-GPIB card that has been working in an 7 year old Vista PC. To test for a newer software version I moved the card to a 64bit Windows 7 PC (after installing the 14.0 drivers) where it...