Intuilink with NI 488.2
I am using HP IntuiLink for oscilloscope screen capture and I switched from an HP I-O card to NI488.2Now I do not see the NI488.2 in InuiLinks configure options.What can I do to get good screen capture...
View ArticleSnap Image with IMAQ
Hi, For some reason, I am unable to talk to the camera I have setup from LabVIEW. If I go to NI-MAX, I can see all of the features of the camera and can directly grab/snap images, but when I use the...
View ArticleWhich type of instrument do I need?
Hi all, I am new to labview and just want to start my experiments but I do not know which NI instruments I'll need. What I want to do is just controlling several devices as follows: 1- Running a...
View ArticleMeasurement and Automation explorer Database Connection Error
Hi,It is the problem of the software called Measurement & Automation explorer(MAX).When I open it, I cannot expand the 'devices & interface'And there appears a MAX Database Connection Error and...
View ArticleSerial Read Write with Porter CM-400
Hi all, I am new to LabVIEW, but have been the assigned the task of automating one of our controllers. I have this guide on how to go about doing this, but am not sure how to do this on LabVIEW. I have...
View ArticleOverloading PCI bus bandwidth with 4 daq cards?
I am attempting to acquire data using one relatively new PC. I have 4 DAQ Cards.. NI PCIe-6323 (x3) and NI PCIe-6353 Each one is sampling data at 800Hz, the first card is reading 32 channels, the...
View ArticleIs it normal for a GPIB device's serial number to be zero?
I am new to using GPIB and the GPIB-USB-HS. I'm writing a C# application, and it's surprisingly tough because the NI4882 help file only says "see the example code" and the three example programs are...
View ArticleCan I use an ethernet cable to connect an old FTIR spectrometer to a PC
Hi, I have aquired an old Perkin Elmer Spectrum 2000 FT-IR spectrometer. The cable for connecting our Spectrum 2000 FTIR spectrometer to a computer is missing. Do you know if it would be possible for...
View ArticleBird Power Sensor
I need to integrate a Bird Power Sensor 5012 on a Virtual Instruments LabVIEW.I have the windows library "BirdDCom.dll" , "BirdSensor.dll" and "HIDLibrary.dll".Can sombody help me to put this sensor on...
View ArticleTektronix TDS 3000 series GPIB-USB control
I have a Tektronix TDS 3032 oscilloscope hooked up to a computer via a GPIB-USB-HS connector. I am trying to control it using the instrument driver downloaded from ni.com. The default setting on the...
View ArticleExternally Control Digitizer
Hi All, I have a question about how to externally trigger digitizer board of a mass spectrometer. Right now TTL pulses from the mass spectrometer were passed to the digitizer trigger in first and then...
View Articleconexion usb pic 18f4550
hola que tal., tengo una duda., no tengo idea de como hacer una conexion por usb de un pic 18f4550., lo que quiero es controlar por medio del labview una sistemas automatico de control de temperatura.,...
View Articlekeithley 2400 SCPI commands for Measurement Speed
Hi,I am using Labview 2012 and Keithley 2420 to measure Current Response Time (Current output vs. Time) for our solar cells. I downloaded the template on keithley's website for I-V curve but modified...
View ArticleGPIB Daisy Chain Addressing Help
I am working on setting up some new equipment, a second setup of one we already have. In both setups, we are using only one GPIB-ENET/100 and one GPIB-232CV-A with LabVIEW. On the original setup,...
View ArticleWhat could cause a VI to change its behaviour depending on if it was run in...
I have tried to collect a list of frequencies used from an Agilent 4294A impedance analyser. I have managed to collect the data but there are a number of additional null/zero values at the start of the...
View ArticleSupport for Old Vibrating Sample Magnetometers
Hello.I am a relative newcomer to LabView and I am trying to get some support for a few older Vibrating Sample Magnetometers (VSM) on behalf of my employer. These machines are quite old and, although...
View ArticleNI 9871 wiring to device with A and B terminals
Hello, I'm trying to install an additional device to a NI 9871 (4 port RS-485) module (in 2-wire configuration) to its 2nd port with no luck. The module communicates fine with one other RS-485 device...
View ArticleHow to save to USB on DPO 4104
Sorry if this is in the wrong place. I am currently automating a test that must set a scope to certain parameters, with a single trigger. Save a screenshot of the triggered response and repeat. I have...
View ArticleSR850 Data to Computer
Hi, I am trying to figure out a way to obtain the data from my SR850 and send it to my computer. I want to send the data via a GPIB cable that is hooked up. I use a labview program called the...
View Articleni-5112 with linux
Hello, I would like to use ni-5112 with SL6. I know that it was born to be used just with win, but maybe someone knows any workaround to use it with the recent drivers as Ni-Scope. I installed it, but...
View Article