Quantcast
Channel: Instrument Control (GPIB, Serial, VISA, IVI) topics
Browsing all 5564 articles
Browse latest View live

Error using VISACOM with the last versions of NI 488.2

Hello,Since the NI 488.215.0.0 drivers, the VisaCom Library doesn't work on GPIB. on Windows 7 and on Windows 8.The "FindRsrc" function doesn't return anything.Dim ResMan As New ResourceManager...

View Article


How do i control bk-precision 9205 using labview? Is it even possible to set...

hello,         i am working on a hardware in loop project and i need to control a Bk- Precision 9205 multi range DC power supply. All i want is to set voltages and currents, give pwn signals and read...

View Article


Having problems taking usb scanned data input into my vi along with gpib...

Gentlemen,I have been trying to integrate the WT500 via gpib; taking instrument data and saving that to a spreadsheet file with headers. Because I have a different DUT each time I test I elected to be...

View Article

Having problems transferring WT500 measurement data from gpib/usb to csv file.

Gentlemen,I have been trying to integrate the WT500 via gpib; taking instrument data and saving that to a spreadsheet file with headers. Because I have a different DUT each time I test I elected to be...

View Article

Image may be NSFW.
Clik here to view.

[HELP] IVI Logical Names Corruption in TestStand and LabVIEW...

I have a test set which contains five instruments which are accessed via IVI calls. NI MAX shows the Logical Names are all set and they are all assigned to the correct instrument drivers. Everything...

View Article


Voltage updates in real time but current does not.

i am using a bk precision 9205 multi range dc power supply and controlling it using labview. I have also connected a DC electronic load to it in CR mode. So as i change voltage the votage read gets...

View Article

Drivers for Delta Design 9023 Environmental Chamber and 9015 controller

I have difficulty in making dd9015ctrl.vi for delta design 9015 controller to work. I am suspecting that my Delta Design 9015 controller might be an older version. Is there a solution to this...

View Article

USB Communication with Sartorius MSA6202S-100-D0 Balance

I am trying to use LabView 2017 to communicate with the Sartorius MSA6202S-100-D0 weight scale.  The scale supports USB, RS232 (DB25 connector) and Ethernet communication, but I am trying to...

View Article


Image may be NSFW.
Clik here to view.

picoscope 4423 gives error while running it with labview.

hiii, i am using a picoscope 4423 and trying to control it using labview. i download an example and when i am running it it gives this error.  the files are added below 

View Article


HOW TO INCREASE OR DECREASE TIME DELAY TO SAVE DATA FROM OSCILLOSCOPE

Hi there, i am using RIGOL 1052E oscilloscope to save data in my laptop using USB interface with Lab View. I am using RIGOL DS1000 series delay VI found from instrument drivers. Default time delay is...

View Article

RMC Watlow ez-zone input/output

Hello, I'm trying to program the labview to control RMC Watlow ez-zone, through the USB/RS-485 serial connector.in its example (driver downloaded from...

View Article

Agilent usb-GPIB 82357B is not shown in NI MAX

I am trying to communicate with a spectrum analyzer through a Agilent USB-GPIB (82357B)Only the USB head of cable is connected to my USB port of my computer and I am trying to check if NI MAX can...

View Article

Slow NI MAX

It takes long time for NI MAX to be open on my PC (Windows10, NI VISA 17.00), Then when it is open I can not open VISA Options window(in tools/ NI-VISA/ Visa Option) and I see either timeout error or...

View Article


VISA automation program for controlling instrument on Mac os

I cannot find a right way of visa automation program for controlling instrument  via Qt on Mac os.I need   c++ sample code  or guidance document  on Mac os.Anybody can give me some proposal for this...

View Article

Connection between LabVIEW and oscilloscope

Hello,I am a starter in LabVIEW, and I have a problem on getting data out from the oscilloscope. The type of the oscilloscope is HM507, and this oscilloscope only has RS232. How do I get the data of...

View Article


GPIB-ENET/1000 Configuration on Red Hat Workstation Linux 6.5

Guys,How do I go about configuring a GPIB-ENET/1000 on a Linux system which doesn't have X Window Graphical System installed? I've installed NI-488.2 15.1.0. Is there a text utility available to...

View Article

How many XNET 'Stream' Sessions can be created per physical CAN Port

I am re-posting this as suggested.This is related to this post: https://forums.ni.com/t5/LabVIEW/Maximum-XNET-Sessions/td-p/3625492 Hi, I created a VI that checks the maximum number 'Stream' sessions...

View Article


NI USB-Serial Adapter disconnects soon after plugging in

   My NI USB-232 is recognized in the Windows 7 "Devices and Printers" menu as 2 icons: "USB-232" and "NI USB-232/1 Communications Port (COM3)". But then the icon disappears after some time, anywhere...

View Article

Suggest Me

Hello everyone i am looking for some hardware tools and some other products Load Cells and controls.

View Article

B1500A no data displayed in Labview

Version:1.0 StartHTML:000000174 EndHTML:000003947 StartFragment:000000431 EndFragment:000003915 StartSelection:000000431 EndSelection:000003915 SourceURL:about:blankHello, I am using Labview for a week...

View Article
Browsing all 5564 articles
Browse latest View live


<script src="https://jsc.adskeeper.com/r/s/rssing.com.1596347.js" async> </script>