Quantcast
Channel: Instrument Control (GPIB, Serial, VISA, IVI) topics
Browsing all 5564 articles
Browse latest View live

GPIB-USB Interface installation/connection

Hello all, I'm using NI LabView2013 for a few months, and now I am trying to connect a power supply (Agilent E3631A) to the computer with a GPIB-USB Interface (Agilent 82357A). I have installed the...

View Article


DPO7014 can’t determine saving CSV data range by programming command

When the scope recall length is 50K, I want to save scope channel 4 full data as csv file. Trying the command as below:data:stop 50000;SAVe:WAVEform:FILEFormat SPREADSHEETCsv;SAVe:WAVEform CH4,...

View Article


telemetry for solar car

Hello everyone!i want to ask about telemetry for solar car system.1.How does telemetry system work in solar car?2.what components do i need to use?really hope someone can help me.thank you.

View Article

DMM 4040

Hello sir,I am using LABVIEW 2010, and am in need to interface DMM 4040 using gpib to the former. What driver would you suggest   for the same?

View Article

Image may be NSFW.
Clik here to view.

PCI-GPIB: BSOD on bootup

Hi All, I am trying to get a system up and running in my lab and I'm having an issue with a PCI-GPIB card. I installed the card and booted the system and bootup was ok. I checked in device manager and...

View Article


Image may be NSFW.
Clik here to view.

USB device shown in NI-MAX, but SOMETIMES VISA Resource name in LabView shows...

Ok so this is the problem Im communicating labview with a MCU using USB Port. The device is recognized in NI-MAX when i plug it in but sometimes it won't show in VISA Resource name,for example last...

View Article

Reading Full Memory Rigol DS4032

I am working on a project that needs to read the full data from a rigol ossiloscope over a network. Right now I can only fetch 1400 data points, the equivalent of a screen grab off the ossiloscope. I...

View Article

ni max

I am working with NI MAX 15.3 on a windows 7 professional PC. I'm connected to my PC to a blackbody source with a cross over cable and am able to PING the blackbody. I want to add the blackbody in NI...

View Article


libnipalu.so failed to initialize

Greetings, We installed NI-VISA 15.0 on RHEL 7.2 (output attached). When running our application, the following error message appeared and the program aborted. The abort happens on the very first call...

View Article


Image may be NSFW.
Clik here to view.

hex over tcp?

Since NI has dropped the ENET-232/4 we have had to look else where to handle our serial communication. I am testing a B&B Electronics VERSR4x4 and 2 out of our 3 instruments use ASCII strings with...

View Article

timeout fails when instrument is turned off

I have a power supply connected to my PC over GPIB using VISA.  Everything seems to work fine, but when I turn off the power supply, and then try a query, VISA seems to just hang for around 30 seconds....

View Article

NI VISAで認識されていた計測器が不明なデバイスになりました

6月16日から6月30日まで正常動作していた発振器が7月1日に不明なデバイスになりました。 VISA503full.exeをインストールして、WF1974(NF)を使用するアプリケーションを作成しました。 6月30日までは、問題なく動作していたのですが、7月1日午後に動作異常が発生し、 確認したところ、OSのデバイスマネージャー上で不明なデバイス(USB Serial Controller D...

View Article

Keithley 6485 picoammeter reading rate via GPIB in LabVIEW

Hi I am fairly new to LabVIEW. I want to take 1000 readings per second through the picoammeter and get them transferred to my LabVIEW program via GPIB. The sample rate is the maximum the device can...

View Article


ASRL COM server

Hi all, I know that it is possible (and I often use it) to configure a VISA server on remote computer in order to allow access from my computer to have access to GPIB device directly connected to...

View Article

Image may be NSFW.
Clik here to view.

Controlling ProScan III X-Y stage with LabView

Hi there,I'm new to LabView and this forum, please excuse me for asking sily questions! I am on a project trying to use LabView for automation PRIOR ProScan III x-y stage to allow Gel mapping. The...

View Article


Keithley 2400 LabView Error -1073807346

I am trying to take a resistance measurement from my Keithley 2400 Instrument and import that data to LabView 2013 SP1. I am running the Keithley example LabView program Read Single (attached). I keep...

View Article

Difficulty Triggering Tek MDO3014

So I am trying to write a VI that waits for a trigger, aquires a waveform and then displays it.  But I want it continuously running so that when I start a new sequence, I do not have to restart the VI....

View Article


Plug and play devices

Hello, I am trying to interface Keithley 2701 DMM with Labview signal express'15. I tried to download Keithley drivers from NI and found two different drivers (...

View Article

agilent 33512B dual channel phase alignment

Using the instrument drivers for the Keysight/Agilent 22500B function generators, how does one align the phase of the dual channel ourtputs o f the 33512B? The pages 162-163 of the user manual discuss...

View Article

VIA 5630 error 0xBFFA4004

Hi We used a VNA PXIe 5630 and when try to execute the calibration  with automatic module ), some time we have the error 0xBFFA4004 .the error occured at function :        public int...

View Article
Browsing all 5564 articles
Browse latest View live


<script src="https://jsc.adskeeper.com/r/s/rssing.com.1596347.js" async> </script>