Visa Serial Communication errors out after about 30-60 minutes of operation

$
0
0

I have a serial communication VI that we run as part of a ~70 minute test. This program is working and the first test station we set it up on is functioning fine. However when I installed on a second station with the same hardware the test throws a VISA error (Hex 0xBFFF0000) Unknown system error after 30-60 minutes of operation, VISA continues to throw errors until the device it's communicating with is reset. I tried swapping the hardware with the working test station and this hardware worked fine on the other computer. The code is also identical, the only difference is the computers, though both are running the same Windows 10 64-bit OS, though they may not have been configured the same way. Is there a Windows setting that may be causing this issue?