Serial VISA 'Write' -why is it slow to return even with large buffer?

$
0
0

Hi,

 

I'm writing a serial data transfer code 'module' that will run 'in the background' on a cRIO-9014.  I'm a bit perplexed about how VISA write in particular seems to work.

 

What I'm seeing is that the VISA Write takes about 177ms to 'return' from a 4096 byte write, even though my write buffer has been set to >> 4096.

 

My expectation would be that the write completes near instantly as long as the VISA driver available buffer space is greater than the bytes waiting to be written, and that the write function would only 'slow down' up to the defined VISA timeout value if there was no room in the buffer.

 

As such, I thought it would be possible to 'pre-load' the transmit buffer at a high rate, then, by careful selection of the time-out value relative to the baud rate, it would self-throttle once the buffer fills up?

 

Based on my testing this is not the case, which leaves me wondering:

 

a) If you try to set the transmit buffer to an unsupported value, will you get an error?

b) Assuming 'yes' to a, what the heck is the purpose of the serial write buffer? I see no difference running with serial buffer size == data chunk size and serial buffer size >> data chunk size??


Viewing all articles